Software application for concurrent <t>hyperspectral</t> imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.
Nir Hyperspectral Camera Wcs Mc 020, supplied by Labsphere Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nir hyperspectral camera wcs-mc-020/product/Labsphere Inc
Average 90 stars, based on 1 article reviews
nir hyperspectral camera wcs-mc-020 - by Bioz Stars, 2026-04
90/100 stars

Images

1) Product Images from "Design and validation of a high-speed hyperspectral laparoscopic imaging system"

Article Title: Design and validation of a high-speed hyperspectral laparoscopic imaging system

Journal: Journal of Biomedical Optics

doi: 10.1117/1.JBO.29.9.093506

Software application for concurrent hyperspectral imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.
Figure Legend Snippet: Software application for concurrent hyperspectral imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.

Techniques Used: Software, Imaging

Phantom assessment of laparoscopic HSI system. (a) External view of SC configuration. (b) Pseudo-RGB formed from the hyperspectral frame in a video sequence. (c) Internal view of the distal end of the laparoscope and visceral tissues.
Figure Legend Snippet: Phantom assessment of laparoscopic HSI system. (a) External view of SC configuration. (b) Pseudo-RGB formed from the hyperspectral frame in a video sequence. (c) Internal view of the distal end of the laparoscope and visceral tissues.

Techniques Used: Sequencing

Result of the spectral accuracy assessment for the NIR hyperspectral camera. HSI (yellow) plotted as mean ± SD (shaded area) versus reference curve (purple).
Figure Legend Snippet: Result of the spectral accuracy assessment for the NIR hyperspectral camera. HSI (yellow) plotted as mean ± SD (shaded area) versus reference curve (purple).

Techniques Used:

Spatial resolution (mm) and PIQUE scores achieved with each  hyperspectral camera.
Figure Legend Snippet: Spatial resolution (mm) and PIQUE scores achieved with each hyperspectral camera.

Techniques Used:



Similar Products

90
Labsphere Inc nir hyperspectral camera wcs-mc-020
Software application for concurrent <t>hyperspectral</t> imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.
Nir Hyperspectral Camera Wcs Mc 020, supplied by Labsphere Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/nir hyperspectral camera wcs-mc-020/product/Labsphere Inc
Average 90 stars, based on 1 article reviews
nir hyperspectral camera wcs-mc-020 - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


Software application for concurrent hyperspectral imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.

Journal: Journal of Biomedical Optics

Article Title: Design and validation of a high-speed hyperspectral laparoscopic imaging system

doi: 10.1117/1.JBO.29.9.093506

Figure Lengend Snippet: Software application for concurrent hyperspectral imaging with the dual-camera system. The left pane shows the live video feed of the camera as raw, mosaic images. The right pane shows a single band from a captured hypercube.

Article Snippet: Another reflectance tile with a calibrated spectral profile extending into the NIR range was used to assess the NIR hyperspectral camera (WCS-MC-020, Labsphere Inc.).

Techniques: Software, Imaging

Phantom assessment of laparoscopic HSI system. (a) External view of SC configuration. (b) Pseudo-RGB formed from the hyperspectral frame in a video sequence. (c) Internal view of the distal end of the laparoscope and visceral tissues.

Journal: Journal of Biomedical Optics

Article Title: Design and validation of a high-speed hyperspectral laparoscopic imaging system

doi: 10.1117/1.JBO.29.9.093506

Figure Lengend Snippet: Phantom assessment of laparoscopic HSI system. (a) External view of SC configuration. (b) Pseudo-RGB formed from the hyperspectral frame in a video sequence. (c) Internal view of the distal end of the laparoscope and visceral tissues.

Article Snippet: Another reflectance tile with a calibrated spectral profile extending into the NIR range was used to assess the NIR hyperspectral camera (WCS-MC-020, Labsphere Inc.).

Techniques: Sequencing

Result of the spectral accuracy assessment for the NIR hyperspectral camera. HSI (yellow) plotted as mean ± SD (shaded area) versus reference curve (purple).

Journal: Journal of Biomedical Optics

Article Title: Design and validation of a high-speed hyperspectral laparoscopic imaging system

doi: 10.1117/1.JBO.29.9.093506

Figure Lengend Snippet: Result of the spectral accuracy assessment for the NIR hyperspectral camera. HSI (yellow) plotted as mean ± SD (shaded area) versus reference curve (purple).

Article Snippet: Another reflectance tile with a calibrated spectral profile extending into the NIR range was used to assess the NIR hyperspectral camera (WCS-MC-020, Labsphere Inc.).

Techniques:

Spatial resolution (mm) and PIQUE scores achieved with each  hyperspectral camera.

Journal: Journal of Biomedical Optics

Article Title: Design and validation of a high-speed hyperspectral laparoscopic imaging system

doi: 10.1117/1.JBO.29.9.093506

Figure Lengend Snippet: Spatial resolution (mm) and PIQUE scores achieved with each hyperspectral camera.

Article Snippet: Another reflectance tile with a calibrated spectral profile extending into the NIR range was used to assess the NIR hyperspectral camera (WCS-MC-020, Labsphere Inc.).